BZQZS - 14571, ARSENIC REFERENCE STANDARD SOLUTION (SUP DAT)
- MSDS: BZQZS
- Manufacturer: HACH CO
- Product Name: 14571, ARSENIC REFERENCE STANDARD SOLUTION (SUP DAT)
- National Stock Number: 6810-01-352-1490
Product Identification
Product ID:14571, ARSENIC REFERENCE STANDARD SOLUTION (SUP DAT)
MSDS Date:09/12/1993
FSC:6810
NIIN:01-352-1490
MSDS Number: BZQZS
Responsible Party
US
Emergency Phone: 303-623-5716
Info Phone: 800-227-4224
Cage: 4T252
Contractor
Telephone: 800-227-4224
Cage: 4T252
Ingredients
ARSENIC TRIOXIDE (SARA 302/313) (CERCLA)
CAS: 1327-53-3
RTECS: CG3325000
Fraction By Weight: <0.5%
OSHA PEL 0.01 MG/M3 (MFR)
ACGIH TLV: 0.01 MG/M3, A1
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SODIUM HYDROXIDE (CERCLA)
CAS: 1310-73-2
RTECS: WB4900000
Fraction By Weight: <1%
OSHA PEL 2 MG/M3
ACGIH TLV: C 2 MG/M3
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
WATER; (DEMINERALIZED)
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: <100%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: ARSENIC TRIOXIDE EXTREMELY
TOXIC. SODIUM HYDROXIDE CORROSIVE, VERY TOXIC. MAY BE IRRITATING TO
EYES AND SKIN. NAUSEA, JAUNDICE, SKIN IRRITATION, NERVOUS SYSTEM
DISTURBANCES. TARGET ORGANS: DIGE STIVE TRACT, CENTRAL NERVOUS
SYSTEM, SKIN, BLOOD, LUNGS, LIVER.
Explanation of Carcinogenicity:ARSENIC TRIOXIDE: IARC MONOGRAPHS,
SUPPLEMENT, VOL 7, PG 100, 1987: GROUP 1. NTP 7TH ANNUAL REPORT ON
(SUP DAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE REPORTED.
First Aid
First Aid:EYES/SKIN: FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES. INGESTION: INDUCE VOMITING BY STICKING FINGER DOWN THROAT.
NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. CALL MD.
INHALATION: RE MOVE TO FRESH AIR.
Fire Fighting
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:SCOOP UP MATERIAL. DECONTAMINATE SITE. DISPOSE
OF THE MATERIAL IN AN EPA APPROVED HAZARDOUS WASTE SITE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE TIGHTLY CLOSED. AVOID CONTACT
WITH EYES, SKIN AND CLOTHING.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:ADEQUATE VENTILATION.
Protective Gloves:DISPOSABLE LATEX GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS (SUP DAT)
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
TRADE NAME/PART #: 1000 + 10 MG/L AS AS+3. CARCIN EXPLAN: CARCINOGENS,
1994: KNOWN TO BE CARCINOGENIC. ANIMAL: LUNG TUMORS. EYE PROT:
GOGGLES AND FULL LENGTH FACESHIELD .
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:0.997
pH:5-7
Evaporation Rate & Reference:1.053
Solubility in Water:MISCIBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID, NO ODOR
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:HEAT, EXCESS EXPOSURE TO AIR.
Hazardous Decomposition Products:MAY EMIT TOXIC FUMES OF ARSENIC IN
FIRE.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/ALL LOCAL, STATE &
FEDERAL REGULATIONS.
======================================================================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.